The C16F3TM160 is a 3-pole, fixed-mounting molded case circuit breaker from Schneider Electric’s ComPacT NSX New Generation range, purpose-built to optimize panel space while delivering reliable overload and short-circuit protection. It’s fitted with a TMD (thermal-magnetic) trip unit rated at 160A, providing adjustable thermal overload protection combined with a fixed magnetic short-circuit trip — a straightforward, cost-effective protection solution for standard distribution and motor-feeder applications.

Rated for an operational voltage of up to 690V AC and a breaking capacity (Icu) of 36kA rms at 380/415V AC, the breaker’s performance scales with voltage — reaching as high as 85kA at 220/240V AC and as low as 8kA at 660/690V AC, per IEC 60947-2. It offers strong mechanical and electrical durability (40,000 mechanical cycles; 40,000 electrical cycles at 440V/In), front-side up and down busbar connections on 35mm pitch, and can be mounted horizontally or vertically flat on its back. Compact at just 105 × 161 × 86mm for the 3-pole version, the C16F3TM160 supports a wide range of optional accessories and auxiliaries, and is compliant with IEC 60947, CCC, EAC, and marine classification standards — making it a solid choice for industrial distribution boards, motor protection panels, and marine electrical systems.

Technical Specification

Attribute Value
Range ComPacT NSX, new generation
Breaker series NSX160F
Poles 3P, 3d
Mounting Fixed
Mounting support Backplate
Mounting position Horizontal and vertical flat on the back
Upside connection Front
Downside connection Front
Connection pitch 35 mm
Dimensions (W × H × D) 105 × 161 × 86 mm
Standards IEC 60947, CCC, EAC, marine classification

Trip Unit

Attribute Value
Trip unit type TMD (thermal-magnetic)
Protection type L (overload, thermal) + I (short-circuit, magnetic)
Trip unit rating 160 A at 40°C
Long time pick-up (Ir) Adjustable

Electrical Ratings

Attribute Value
Rated operational voltage (Ue) 690 V AC, 50/60 Hz
Rated insulation voltage (Ui) 800 V AC, 50/60 Hz
Rated impulse withstand voltage (Uimp) 8 kV
Breaking capacity (Icu) — 220/240V AC 85 kA
Breaking capacity (Icu) — 380/415V AC 36 kA
Breaking capacity (Icu) — 440V AC 35 kA
Breaking capacity (Icu) — 500V AC 30 kA
Breaking capacity (Icu) — 525V AC 22 kA
Breaking capacity (Icu) — 660/690V AC 8 kA
Breaking capacity (Icu) — 480V AC (UL 508) 35 kA
Rated service breaking capacity (Ics) Same as Icu across all voltage points above

Durability

Attribute Value
Mechanical durability 40,000 cycles
Electrical durability 40,000 cycles at 440V/In (220,000 at reduced load) · 15,000 cycles at 690V/In (27,500 at reduced load)

Environmental

Attribute Value
Operating temperature −25°C to 70°C
Protection degree IP40
Max. relative humidity 95%